4 resultados para Ondas - Tensão

em Repositório Institucional da Universidade Estadual de São Paulo - UNESP


Relevância:

30.00% 30.00%

Publicador:

Resumo:

It is important to ensure smoothly operation of a transmission line, sending energy to the consumption centers with minimal interruptions and safer. With this necessity, the fault location techniques have grown, in order to mitigate the impact of the fault and its correction can be more quickly and accurately. This paper presents a comparison between two different techniques of fault location, the fault location by impedance method, which uses the line parameters, the impedance per distance, voltage and current signals, and the other is the traveling wave method, which uses only a very fast analysis of time, synchronization and length between the line ends, do not using voltage and current values, but the temporal perception of the fault. Using travelling waves fault detection makes the previous knowledge of line parameters obsolete, which helps a lot network technicians and engineers with a quick and easy analysis. The methods are simulated in ATP Draw software, so both algorithms can be evaluated for their effectively and accuracy

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we will present an overview of the smart grid defining the three main systems that compose it: smart infrastructure system, smart management system and smart protection system. We will conceptualize a functionality of smart management system, the conservative voltage reduction, citing its benefits and its history of application. And, finally, we'll cover a test in which we reduce the nominal voltages on incandescent bulbs, CFL and LED, in the context of residential lighting, and on LED and HPS, in the context of public lighting. The test aims to check whether the voltage reduction adversely affects sources of lighting by measuring the temperature manually with a thermal imaging camera FLIR and illuminance with a LUX meter. The set of power factor, total harmonic distortion, and input power values will be collected automatically through the power quality Analyzer Fluke 345 with a probe Fluke Hall Effect Current. For residential lighting, it was found that both CFL and LED had good performance with the smallest variations in illuminance. Between both, the LED source had the lowest harmonics and the lowest power consumption, on the other hand incandescent bulbs had a bad performance as expected. Public light sources also had a good performance and obtained power factors within the standards, as opposed to the CFL and LED residential sources. The data collected clearly shows the feasibility for nominal voltage reductions. Even with small reductions, there are possibilities of savings which can be passed on to the utilities and consumers